Release date: 2024-06-14
|
New feature: |
Two lane DisplayPort alternate mode is now available as well in case the four lane alternate mode setting is not supported.
|
FlowControl handling on serial port is now supported.
|
Power Management change. PoE "auto" mode option has been removed.
|
LARA 1.2.0b40 integration.
|
Critical issues have been fixed at the launch of the LARA configurations.
|
USB access is available via service port for demonstrating and piloting the StreamDeck device support in LARA.
|
A critical issue has been fixed at the USB-C Ethernet connection.
|
New experimental LW3 node is available for testing now: EXPERIMENTAL/MEDIA/USB/Service.Enabled.
|
Taurus TPX-TX20 and HDMI RX communication channel has been significantly improved. Further upgrades are coming.
|
Password history is now maintained on web authentication. The past ten passwords are no longer available to used.
|
UCX-4x3-TPN-TX20 is now officially supported.
|
UCX-2x1-TPN-TX20 is now officially supported.
|
Known issue: |
USB-C Ethernet connection occasionally disconnects the connecting devices.
|