1

1. Basics and Building Blocks

Thank You for choosing LARA. In the first chapter we would like to introduce the software, highlighting the most important features in the sections listed below:

1.1. Introduction

What is LARA?

Lightware Advanced Room Automation (LARA) is a future-proof room automation platform. This software can be used for making controlling functions in meeting rooms.

Where Can You Find It?

It runs integrated in Taurus UCX, DCX, UCX-TPX, UCX-TPN, MMX2 series devices and the TPN-CTU-X50 control unit, configurable via a browser. Meeting participants can control the devices in the room through a touch panel.

Basics

Room integration

The keyword is: room. LARA is developed for meeting room size environment.

Separated SW tool

LARA is part of the Lightware product, however, it is an independent entity in the device. Since the device is protected with a password, LARA is also safe from unwanted modifications.

Availability

LARA is available in Taurus UCX, Taurus DCX, UCX-TPX and UCX-TPN devices, as well as in MMX2 and TPN control box devices.

Key Benefits

Open Integration

Controlling any device that supports open protocols (REST, TCP/IP, LW3, etc). No need for certificated training, as LARA is based on JavaScript.

No External Controller

LARA is in the Lightware products (for now in Taurus and MMX2) and can be used to connect and control third-party devices. No need to purchase an extra controller box.

Up/downloading the Configuration

The full LARA configuration can be downloaded as a ZIP file. The file can be uploaded to the same device or to another device of the same type.

LARA is Expandable

The modular structure, the re-usable Modules and the continuous development mean more and more new features. The software contains many variable built-in factory modules and can be expanded with downloadable contents as well.

Solution for Meeting Rooms

LARA is a software platform that has been designed mainly for controlling meeting rooms. While developing LARA, the experiences of the popular Event Manager - which can be found in numerous Lightware devices - have been applied. The platform is designed and developed by Lightware Visual Engineering.

With LARA, you can automate your meeting rooms, create or re-use software Modules by using the power of JavaScript, control the behavior of the Taurus and connect it to other third-party devices or services, or do virtually everything that is possible.

Supported Devices

LARA is available in the following devices:

UCX-2x1-HC30

UCX-2x2-H30

UCX-4x2-HC30

UCX-4x2-HC30D

UCX-2x1-HC40

UCX-2x2-H40

UCX-4x2-HC40

UCX-4x2-HC40D

UCX-4x3-HC40

UCX-2x1-TPX-TX20

UCX-4x3-TPX-TX20

UCX-3x3-TPX-RX20

UCX-2x1-TPN-TX20

UCX-4x3-TPN-TX20

DCX-2x1-HC10

MMX2-4x3-H20

MMX2-4x1-H20

TPN-CTU-X50

LARA Version

ATTENTION!The LARA versions may contain big differences. This User's Manual is based on a certain version of LARA that is displayed on the bottom of each page. Please check the LARA version of your device. LARA comes with the Taurus/MMX2/TPN-CTU-X50 firmware package and we always recommend to update the firmware of your device to the latest version.

1.2. Limitations and Capabilities

Please consider the following when using LARA:

The Taurus/MMX2 configuration contains the whole LARA configuration as well. If the device configuration is handled with Bulk management or with the Backup/Restore feature, LARA settings can be preserved.

If LARA is running when the Lightware device (that runs LARA) is restarted, LARA will run automatically again.

A connected or an external device can be accessed via an Instance. (See more information about the Instances in the Modules and Instances section.)

When LARA is running, all the defined Instances run together.

At most 20 Instances can be run parallel if the complexity of the Instances are at 'average' level (see the specification below of a complex sample configuration).

The storage space is 128 MB for the Modules, Instances, user Module content and all codes.

The available RAM is 128 MB, LARA uses 56 MB in factory default state.

Restoring the factory default settings in the UCX/MMX device will delete the LARA configuration. This also happens during a firmware update if the firmware version is v2.0 or below.

The Specifications of a Complex Sample Configuration

It consists of 8 Instances:

=5 from the Generic-tcp-ip-client Module,

=1 from the Taurus-ucx-ctu-mmx2 Module

=1 from the User panel Module, and

=1 from the Logic Module.

This configuration needs cca. 87 MB RAM space when running.

1.3. How to Access?

Short Steps

Step 1.Setting the password in the desired UCX/MMX2 device.

Step 2.Enabling port #443.

Step 3.Enabling LARA in the device.

Step 4.Opening LARA in a browser.

Detailed steps

Step 1 – Setting the Credentials in the Desired Taurus Device

Start the LDC software and connect to the device or open the web LDC in a browser typing the IP address of the device into the address/URL bar.

Navigate to the Settings/Services tab.

Set a password for the user 'admin' (if not set previously) and Save it.

Step 2 – Enabling Port #443

Navigate to the Settings/Services tab in LDC or in web LDC.

See the Network services section and mark the Enable port 443 setting.

Step 3 – Enabling LARA in the Device

Navigate to the Settings/Services tab in LDC or web LDC.

See the Network services section and mark the Enable LARA (factory default state is disabled).

Step 4 – Internal Time Setting

For the proper working in Taurus and LARA, the internal clock must be synchronized with an NTP server. You can create time-sensitive Rules where the exact time and date is essential. The preparation shall be done in the UCX/MMX2 device:

Navigate to the Settings/System tab in LDC or web LDC.

Enable NTP by the switch in the Set Date & Time secion.

Set the NTP server according to your needs.

Step 5 – Opening LARA in a Browser

Open a web browser and type the following in the address line: (make sure to type https)

https://<IP_address>/lara

TIPS AND TRICKS:If you select the Settings/System tab, you can open LARA with the OPEN LARA button.

After that you have to enter the user admin and the set password.

ATTENTION!Due to a known issue a malfunction occurs during login. After pressing the login button you will be directed to the web LDC instead of LARA. Navigate to the https://<IP_address>/lara page again to open LARA.

ATTENTION!Session management for security reasons is introduced in UCX and MMX2 devices. When you log into LARA (or in Taurus web LDC) a TCP session is started. After 25 minutes of inactivity you are prompted to confirm to continue the session (in five minutes) or you will be logged out. After two hours you will be logged out automatically regardless of activity.

ATTENTION!Due to a known issue there is a malfunction in Session management: you have to confirm to continue the session every 25 minutes despite the continuous activity.

INFO:When opening LARA for the first time or after factory reset, you must accept the disclaimer statement.

The Status Board of LARA – in Factory Default State

1.4. Expanding LARA with Modules

LARA can be expanded with various type of modules (see more details in the The Structure of LARA section on the next page) for the best fitting to the installed AV system.

Two methods is available to add modules to the software:

Browsing a built-in factory module;

Downloading a module from Lightware's website and adding to the software.

Built-in Factory Modules

Step 1.Select the Browse Modules menu.

Step 2.Select the icon to add a new factory module.

Step 3.Select the icon to define an instance for the module.

Downloading a Module from the Website

Step 1.Visit the https://lightware.com/products/software/lara-software website and select the File Downloads section. Many downloadable LARA modules can be browsed there.

Step 2.Download the .zip file to the local computer. The package does not need to be unzipped.

Step 3.Add the new module to the Modules section using a simple drag & drop method.

Step 4.Enter the name of the Module.

Step 5.Select the icon to define an instance for the module.

1.5. The Structure of LARA

1.5.1. Modules and Instances

Modules

The Module is the basic building block of LARA. The main purpose of the modular structure is to create re-usable units. The Modules have different functions:

Driver Module

Connecting to a device in the room.

Logic Module

Creating the connection between other Modules by defining Rules and the working logic.

User Panel Module

Providing a Graphical User Interface (GUI) for the end-users, e.g. Touch screen control.

Script Module

Any custom software for a specific purpose,

e.g. Cisco Webex Module.

ATTENTION!Please note that the Script Module gives freedom for the user but might break the existing configuration of the LARA. Use this module carefully.

Instances

The Module cannot be used by itself, an Instance has to be created from it. This way of working can be demonstrated with a simple example: if you have an executable file on your computer, that is a Module. When you run it once or multiple times, the windows are the Instances. The software pieces are identical behind the running Instances, however, you can modify their behaviour by giving them different Parameters at start.

Parameter and Value

The modular structure has an effect on the Parameter handling:

The definition of a Parameter: stored in the Module.

The value of the Parameter: stored in the Instance but the default value is stored in the module.

For example: You have two Taurus devices, so you create a Taurus Module. You have to create two Instances and each Instance will contain the IP address of the desired Taurus device.

Driver Module

If you want to make a connection between LARA and an external device, a Driver Module is necessary.

INFO:Everything that is outside LARA is 'external'. The device that runs LARA is also considered external, too. That's why you have to create a Taurus Driver for UCX/MMX2 devices.

The Driver Module can be:

Device-specific Driver: e.g. Taurus / MMX2 Driver, Generic Lightware LW3 Driver

Communication Driver: e.g. Generic TCP Client Driver, Generic REST API Client Driver

LARA comes with built-in (factory) Modules but you can create your own Module as well, see the Factory Module Descriptions and User Module Descriptions chapters.

Logic Module

The Logic Module describes the working logic of the room and/or it can be used for interactions between other Modules. A logic Module creates the connection between the Modules with Rules.

User Panel Module

The User panel Module provides a GUI for the end-users for controlling functions in the room, like a Touch screen controller. HTML content can be uploaded to the Taurus as a pre-formatted HTML file, and it can be edited in the code editor later. The HTML file can be opened in the Touch screen controller. The Module allows modifying the visible elements of the touch screen that makes the GUI interactive. See more information in the User Module Descriptions chapter.

The Inside of the Module

The Connection of a Driver Module and the Instances

1.6. The Parts of the Automation

RULE = TRIGGER [ +CONDITION ] & ACTION

Rules

The Rule is the part of the Module where the automation steps are described. You can define the following main parts:

Trigger: a specific change has happened.

Condition (optional): if a Condition is set, it has to be fulfilled to run the Action.

Action: execute one or more operations.

The Parts of the Automation – With and Without a Condition

Example

Trigger: occupancy sensor sends a signal (GPIO P1 level is high).

Condition: a laptop is connected (signal is present on I1).

Action: switch on the display, show the laptop image (swith I1 to O1 port and send "powerON" command to the display).

The details of the automation can be found in the The Automation Process section.

2

2. Start Using LARA

This chapter is about the structure and the main parts of LARA.

2.1. The Main Screens

2.1.1. The Status Board Tab

LARA status icon

/ LARA configuration is running / not running

Restarting LARA

: press to restart LARA configuration

Running LARA

/ : press to start / stop LARA configuration

Instances

List of the currently defined Instances of any Modules with a status icon.

Log window

Displaying system messages, but custom messages can be also displayed. The section is resizable or it can be hidden by the down arrow:

Instance buttons

: Editing the Parameters of the Instance.

: Editing the parent Module.

: Opening the Methods and Events testing page.

: Deleting the Instance.

: QR code and link to the Web page of a User panel Module.

Info labels

Only displayed if LARA configuration is running, in order to show valid information. For customizing labels, see the Status Variables section.

2.1.2. The Browse Modules Tab

Modules

List of the used Modules. By pressing the down arrow ,, , the submenu is opened.

: The Module has no Instances.

: Instance is created from the Module.

Module Handling Buttons

: Creating a new Module from scratch or from a base Module template.

: Uploading a new Module from a ZIP file.

: Creating a new Instance from the selected Module.

Module Editing Buttons

: Updating the Module. If you upload a configuration/Module, it may contain a newer version of a Module than the existing one of your configuration and this button is displayed. You can update the Module in your LARA with this button. See more information in the Module Update section.

: Resetting the Module to the original state.

: Downloading the Module (ZIP file).

: Deleting the Module (and all of its previously created Instances).

2.2. General Features

When the Firmware is Updated

If the firmware is updated with FW package v2.1 or newer version, the settings of the UCX/MMX2 device can be preserved, as well as the LARA configuration.

Configuration Download and Upload

The full LARA configuration (including Modules, Instances and Parameters with passwords as well) can be downloaded as a ZIP file. The file can be uploaded to the same device or another device of the same type. Use the Upload Configuration/Download Configuration buttons in the upper menu.

Factory Reset

All Modules and Instances can be deleted (after confirmation) by pressing the button.

Module Update

LARA contains factory Modules that cannot be removed. If you upload a configuration/Module, it may contain a newer version of a Module than the existing one of your configuration. In that case, a blue icon is displayed in the Browse Modules page:

You can update the Module by pressing the button and the new version will be available in your device.

ATTENTION!Please note that the custom code disappears when updating the module.

INFO:Parameters, Events, Methods and Rules defined by the user in a factory Module are preserved when updating to a new version.

Log Window

The bottom part of the window can be toggled to show the log screen. The messages from each running Instance can be viewed here in real time, so you can follow the state of your system. You can view all Instances at same time or filter the messages to only one Instance. The section is resizable or it can be hidden by the down arrow:

TIPS AND TRICKS:The content of the log window can be copied to the clipboard.

2.2.1. Old/new Version Handling

If you want to update the firmware of your Lightware device that runs LARA, the best way is the follow these steps:

Step 1.Download the LARA configuration (for backup).

Step 2.Update the firmware of the device.

Step 3.Normally, the LARA configuration is kept as is, but if the factory default settings restored from some reason and the configuration disappeared, upload the backup configuration file.

Step 4.The new firmware may contain modules that are newer than in the running configuration. In that case, if you press the blue icon , the module will also be changed to the new one in the configuration. This step is recommended only if the module does not contain custom mode.

ATTENTION!Please note that the custom code is deleted when updating the module.

2.3. The Automation Process

The Main Parts of a Rule – With and Without a Condition

ATTENTION!If your configuration contains more than one Module, it is recommended to create the Rules and the additional components (e.g. unique Methods) in a Logic Module.

2.3.1. The Rule

DEFINITION:The Rule is the part of the Module where the automation steps are described.

List of Rules

The user-defined Rules are listed here.

Rule-handling buttons

Delete a Rule

Enable/disable a Rule

Add new Rule

User-defined Rules can be added with this button.

Trigger panel

Defining the Trigger.

Condition panel

Defining the Condition(s), optional.

Action panel

Defining the Action steps.

2.3.2. The Trigger

DEFINITION:The Trigger is the occurence (something has changed) that starts the automation process.

Duration Setting

If set, the Trigger must be detectable throughout the Duration time to launch the Action.

Trigger Types

In case of Taurus UCX/MMX2 Module, the following options are available:

Event

The type means: 'something has happened'. This Trigger type is the same EVENT entity that has been used in previous LARA versions.

Variable Changed

A status variable is changed, but the value does not matter, only the fact of the change.

The 'Variable changed' Trigger type and the Actions

Variable Changed to Value

The new value can be evaluated with the following operators:

The 'Variable changed to value' Trigger type and the Actions

INFO:Above working method is valid in case of the Less than/Greater than operators, too.

Variable Changed Into Range

This type can be used only for number/any types. The options are similar as above, but in this case you can define a range instead of a specific value. The limit values are included in the range.

The 'Variable changed into Range' Trigger type and the Actions

ATTENTION!Due to a known issue a malfunction occurs at this Trigger type as the Action should also be run at the red dot marked moments by design. The error will be corrected in a later LARA release.

Time-based Trigger

The Trigger is fulfilled if the current date/time meets the set value.

ATTENTION!For a proper working the Network Time Protocol (NTP) settings must be set precisely. See the Step 4 – Internal Time Setting section.

The Trigger Panel

The Trigger Panel in the Rule Editor

List of Rules

The user-defined Rules are listed here.

Add new Rule

Custom Rules can be added with this button.

Name of the Rule

Type of the Trigger

As follows:

Event

Variable changed

Variable changed to value

Variable changed into range

Time-based Trigger

Variable selector

In case of Status variable-based Trigger you can select the variable here.

ATTENTION!When LARA is started, the Status variables are empty in the first moment, if default value is not defined. Then the Status variables are updated immediately, but this 'value change' in the background will launch the 'Variable changed' Trigger types. This may cause Actions to execute. If default value is defined for the variable, this phenomenon can be avoided.

DIFFERENCE:If you have a configuration created with a previous version of LARA, the Events in the Rules are converted to Event-type Triggers.

See more information in the Status Variables section.

'Event' vs. 'Status Variable'

In many cases, you can set the Trigger type as an Event or use a Status variable for the same purpose. Actually, the Event is kept in LARA for compatibility reasons mainly. But there is also another reason to use Status variable instead. If you have a configuration with many Instances and you run the LARA configuration, the Instances are not started at exactly the same time but with a minimal delay – after each other. If a Rule refers to an Instance that has not been started yet, it may happen that the Event would not occur in that moment but later. If your configuration is built with only Status variables as Triggers, this would not happen due to the different working pecularity.

Time-based Trigger

ATTENTION!For a proper working the Network Time Protocol (NTP) settings must be set precisely. See the Step 4 – Internal Time Setting section.

This option is to create a Rule that is triggered by a date/time-related occurance. If the current date/time matches with the set date/time setting (and if the Condition is fulfilled), the Action can be run – select the Once option.

The Trigger Panel

2.3.3. The Event

The Event means: something happened. Former LARA versions do not have Trigger but Event. The best way to use is to define a simple occurance as an Event and use the other Trigger types for more complicated cases.

2.3.4. The Condition

DEFINITION:The Condition is one ore more criteria that can be used together with the Trigger to allow running the Action step(s).

Optional, but if it has been set, it has to be fulfilled to run the Action. The way it works: if the Trigger occurs and the Condition can be detected in that moment, the Action can be launched. If the Condition cannot be detected, the Action will not be launched and the Rule process is finished. The process will start again if the Trigger occurs.

For defining Conditions the following options are available:

Defining only one Condition,

Defining more Conditions under 'Match ALL of the following' section (this means 'AND' logic): all the defined Conditions must be fulfilled at the same time to run the Action.

Defining more Conditions under 'And ANY of the following' section (this means 'OR' logic): if any of the defined Conditions is fulfilled, the Action can be run.

Duration Setting: if set, the Condition must be detectable throughout the Duration time to launch the Action.

ATTENTION!The Duration time is not measured from the Trigger but from the last change of the Status variable. This special feature is valid only if the Condition type is Status variable.

ATTENTION!The logic connection between the two groups is 'AND'.

The Conditions Panel

2.3.5. The Method

DEFINITION:The Method is a pre-defined operation that can be executed as an Action of a Rule.

Methods are just like functions that can be called as an Action of a Rule. The Method can be a factory default Method or a user-defined custom Method. Some typical examples from the Taurus UCX/MMX2 Module:

GET: querying a Parameter

SET: setting a property

OPEN: subscribing to a node path

CALLMETHOD: calling an LW3 Method

The Method Editor Panel

List of Methods

The factory default and the user-made Methods are listed here.

Add new Method

User-defined Methods can be added with this button.

Name of the Method

Editing the Method

Factory Methods cannot be edited. The icon is displayed if the mouse cursor is above the Method.

Deleting the Method

Factory Methods cannot be deleted. The icon is displayed if the mouse cursor is above the Method.

User-defined Methods

A Method can be added as follows:

Step 1.Press the Add new Method button in the Methods submenu.

Step 2.Press the button to edit the Method.

Step 3.Name the Method.

Step 4.Add new Method Parameter by the button (optional).

Step 5.Press the Add Method step button in the Code section and define the desired task with the Wizard. The available Action types are the same as described in connection with the Action steps – see the following section. Or select the Code editor and type a custom JavaScript code.

Step 6.Press the Save button.

INFO:The Method Parameter and the Return value can be defined via LARA GUI, the value can be assigned with the Events and Methods debug window. Even tough, the value assingment is not available with Wizard yet but with the Code Editor.

Testing a Method

You can easily try if the defined Method works as it should. Closing the log window is recommended as it may cover the pop up window.

Step 1.Navigate to the Status board.

Step 2.Select the desired Instance and press the button (see below). A new window will pop up showing the defined Events and Methods.

Step 3.Scroll to the desired Method. The desired Method Parameter values can be entered in the textboxes.

Step 4.Press the Invoke <Method_name> Method button.

Testing a Method

2.3.6. The Action

DEFINITION:The Action (step) is pre-defined task (operation) that is executed as the part of a Rule.

The Action is part of a Rule. Lightware-made Modules contain default Action types as follows:

Invoke Method: a pre-defined Method (factory or user) can be run.

Log message: a message to display in the log window (this can be a constant or a dynamic value).

Dispatch Event: a pre-defined Event can be emulated (as if it has happened).

Wait: setting a delay (in ms) before/after an Action step.

Display information on Status board: a constant or a dynamic value (e.g. a Status variable) can be displayed in the log window; see the Displaying a Status Variable on the Status Board section.

Set Status Variable: the value of a variable can be set.

User-defined Action Steps

The Action steps can be added as follows:

Step 1.Create the desired step as a Method (see the previous section).

Step 2.Navigate to the desired Rule and set the Action: select the Invoke Method option.

Step 3.Select the previously set Method from the list.

Wizard vs. Custom Code

The Action step can be added with the Action Wizard or with the Code Editor as a JavaScript code (based on nodeJS programming language).

ATTENTION!If you change anything in the code, the wizard cannot be used to edit the Action step after that. Furthermore, if you use the wizard after the code editor, the new content would overwrite the code.

2.4. Info Labels

Factory default modules contain Info labels that are displayed on the Status Board but custom labels can also be added.

The following notes are referring to the labels:

The order of the labels depends on the starting sequence of the Methods.

Factory defined labels are being kept up-to-date continuously.

The custom labels can be the following:

=The value of a Status variable (e.g. GPIO P1 output value), see the Displaying a Status Variable on the Status Board section,

=A constant value (e.g. 'Hello World!'), see the Displaying a Constant Message on the Status Board section,

=An Instance parameter (e.g. the IP address), see the Displaying an Instance Parameter on the Status Board section,

=A method parameter (only if it is defined as a method step).

Custom Info Labels (marked) and the Default Labels

2.4.1. Displaying a Status Variable on the Status Board

Factory default modules contain Info labels that are displayed on the Status Board but custom labels can also be added. The label can get the value from a Status variable either as follows:

You can display a Status variable as an Info label on the Status board as follows:

Step 1.Create a Rule and define a Trigger, or select an existing Rule.

Step 2.Press the Add rule action step button in the Action section (Wizard tab).

Step 3.Name the step and select the Display information on Status Board option.

Step 4.Type a label.

Step 5.Select the Status variable value type.

Step 6.Select the desired Status variable.

Step 7.Optionally set the style of the label.

Step 8.Press the Save button (this will close the pop up window) and press Save button in the main window, too.

INFO:The Displaying information on the Status board step can also be defined as a Method.

Example

The following example is about a case when a Status variable is selected from the default list and displayed on the Status Board as an Info label (GPIOP1).

Target

If the GPIO P1 output level is changed, the level is displayed and updated on the status board.

Operation

The label is displayed on the Status Board when LARA configuration is started. Once the output level of GPIO P1 is changed, the value is updated.

INFO:The 'GPIOP1' label appears when LARA is started. The Status variable is empty in the first moment (as this Status variable does not have default value). After that the Status variable is updated immediately. This 'value change' in the background would launch the 'Variable changed' Trigger type.

Preparation

Taurus UCX/MMX2 Driver is defined under the Modules menu.

Instance is created from the Module.

The direction of the P1 port is set to Output.

Adding a New Rule

Rule name: e.g. Displaying GPIO P1 level

Trigger Type: Variable changed

Variable Changed: gpioP1Output

Action / Add Rule Action step

=Action name: e.g. GPIO1 update

=Select Action step: Display information on Status Board

=Label: e.g. GPIO1

=Value: Status variable, gpioP1Output

=Style: as you wish

TIPS AND TRICKS:This Rule can easily be tested by toggling the GPIO Pin1 output level in LDC or web LDC.

2.4.2. Displaying a Constant Message on the Status Board

You can display a constant message as an Info label on the Status board as follows:

Step 1.Create a Rule and define a Trigger, or select an existing Rule.

Step 2.Press the Add rule action step button in the Action section (Wizard tab).

Step 3.Name the step and select the Display information on Status Board option.

Step 4.Type a label.

Step 5.Select the Constant value type.

Step 6.Type the message that you want to be displayed as a Constant value.

Step 7.Optionally set the style of the label.

Step 8.Press the Save button (this will close the pop up window) and press the Save button in the main window, too.

Constant custom message on the Info label

2.4.3. Displaying an Instance Parameter on the Status Board

You can display a parameter as an Info label on the Status board as follows:

Step 1.Create a Rule and define a Trigger, or select an existing Rule.

Step 2.Press the Add rule action step button in the Action section (Wizard tab).

Step 3.Name the step and select the Display information on Status Board option.

Step 4.Type a label.

Step 5.Select the Instance parameter value type.

Step 6.Select the desired Instance parameter (e.g. ipAddress).

Step 7.Optionally set the style of the label.

Step 8.Press the Save button (this will close the pop up window) and press the Save button in the main window, too.

IP address of the device is displayed on the Info label

2.5. Status Variables

DEFINITION:The Status Variable can be used to store a piece of information. e.g. the value of an LW3 property.

Application Modes

Value assignment: storing the value of a property,

Displaying Information on the Status Board (Info Label),

Using as a reference in Rules, see the The Trigger section.

INFO:LARA stores the timestamp of the last change of the variable. Time-sensitive Rules are based on that information (duration setting), see the Time-based Trigger section.

Value Assignment

Default Status Variables

The factory default Status variables are connected to LW3 properties and they are kept up-to-date in the background continuously.

For creating a unique Status variable and assigning the value, see the following section.

User-defined Status Variables

INFO:Creating the Status variable in the Logic Module is recommended.

You can create a new Status variable as follows:

Step 1.Navigate to the Status variables menu.

Step 2.Press the Add new button in the middle section.

Step 3.Fill the Name and Type fields; Description and Default value are optional.

Step 4.Press the Save button.

Variable types

number: for storing numbers (decimals are accepted, divided by a dot).

string: for storing characters and text.

boolean: true/false.

json: any kind of JSON object can be stored.

any: any of the types above but without requirements.

ATTENTION!If you use comma as a decimal separator for a number, the value will be handled as a string.

Changing the Value of a User-defined Status Variable

The value of the Status variable can be changed with a Rule Action step or with a pre-defined Method. The value can be:

Constant: a static value determined in this window,

Instance Parameter: the value is coming from the selected Instance. (The Parameter is defined in the parent Module and the value can be different for each Instance. See the The Inside of the Module section.)

Status variable: the value of another Status variable.

Method parameter (only if the value is changed with a Method): the parameter defined in the module.

INFO:The status variables can be displayed on the status board (info label). See the step-by-step description about it in the Displaying a Status Variable on the Status Board section.

2.6. Best Practices

How to Build Your Configuration

When building a LARA configuration with more, than one modules, it is worth to pay attention to:

Set the device-specific Methods, Rules and Status Variables in the Driver and Script Modules.

Set the Room automation related Rules and Status variables in the Logic Module.

When using a User Panel Module, set the HTML-related Events and Rules in the User Panel Module.

These principles help to create re-usable Modules.

Adding a New Module

As mentioned previously, the Driver Module is the interface to a device. A Module can be added on the Browse Modules page with:

Pressing the button and selecting from the available list, or

Pressing the button and adding a previously saved Module (as a ZIP file).

ATTENTION!The default Methods, Parameters and codes of the factory Modules cannot be edited/deleted.

TIPS AND TRICKS:The modul (as a ZIP file) can be added via mouse drag&drop into this window.

Creating Instances

Step 1.Navigate to the Browse Modules page.

Step 2.Press the icon in the top of the Modules section.

Step 3.Type a name for the Instance and optionally set the value of the defined Parameters (if any).

Step 4.Press the Save button.

INFO:Please note that the name of the Instance cannot be changed in LARA after first saving.

The value of the Parameters can be set later as well:

Step 1.Navigate to the Status Board.

Step 2.Press the button in the end of the desired Instance line to open the Parameter editor window.

TIPS AND TRICKS:The Parameters and values of the Instance (seen on the screen) can be saved as a JSON file by the download button. Previously downloaded Parameters and values can be uploaded at this step by the upload button.

2.7. JavaScript Code Examples

The Modules may contain custom codes based on nodeJS programming language. Please find below the following JavaScript example codes that could help you write your custom codes.

Writing something to the log window (comments can be written after double slash)

console.log('Hello world!'); //this is a comment

Writing an error message to the output console (seen at the bottom part of the window, written in red)

console.error('Oh, no! Something terrible has happened!');

Accessing Instance Parameters

console.log('Device IP address is ', params.ip_address);

Waiting for 2000 milliseconds

await new Promise(r => setTimeout(r, '2000'));

Showing/updating information on status board with a given color

this.instance.updateStatus('Today weather', 'Sunny', {color: 'yellow'});

Emitting an Event from an Instance

this.instance.dispatchEvent('resulutionChanged', '1920x1080p60');

Running a custom code 10 seconds later

console.log('Enable the relay');

setTimeout(()=>{

console.log('Disable the relay');

},10000);

Running a code every 5 seconds

setInterval(()=>{

console.log('This is printed every 5 seconds');

},5000);

Running an Action when our Instance has fired an Event

this.instance.on('messageReceived', (message) => {

console.log('A message has just been received:', message)

});

this.instance.dispatchEvent('messageReceived', 'Meow');

Running an Action when another Instance has fired an Event

this.getInstanceById('display').on('volumeChanged', (message) => {

console.log('The display volume has just been changed:', message)

});

Invoking a Method from our own Instance

this.myFancyMethod(param1, param2);

Invoking a Method from another Instance

await InstanceApi.getInstanceById('display').send('powerOn');

Importing nodejs built-in Modules (see this documentation about the available Modules)

//import net Module

var net = require('net');

Writing a file

this.fs.writeFileSync(this.Instance.getLocalStoragePath()+'/data.txt', 'Hello world');

Reading a file

var data = this.fs.readFileSync(this.Instance.getLocalStoragePath()+'/data.txt');

More information and examples about file operations: https://nodejs.dev/learn/the-nodejs-fs-Module

Sending and receiving response to/from a client over TCP/IP

var net = require('net');

var client = new net.Socket();

client.connect(1337, '192.168.1.1', function() {

console.log('Connected');

client.write('Message from the Client.');

});

client.on('data', function(data) {

console.log('Received: ' + data);

client.destroy(); // terminate client after server's response

});

client.on('close', function() { console.log('Connection closed');

});

Sending an HTTP GET message

const http = require('http');

http.get('http://192.168.0.1', (res) => {

const { statusCode } = res;

const contentType = res.headers['content-type'];

if (statusCode !== 200) {

console.log('Request Failed. Status Code: ', statusCode);

res.resume();

return;

}

res.setEncoding('utf8');

let rawData = '';

res.on('data', (chunk) => { rawData += chunk; });

res.on('end', () => {

console.log('Received: ', rawData);

});

}).on('error', (e) => {

console.error('Got error:',e);

});

2.8. External Links

The following documentations help becoming a more professional user of LARA:

The webpage of LARA:

https://lightware.com/lara

The nodeJS programming language – for creating custom codes:

https://nodejs.org/en/docs/

The markdown formatting – for editing a cool Module description:

https://daringfireball.net/projects/markdown/

Reserved Words – good to know when defining Parameters:

https://www.w3schools.com/js/js_reserved.asp

3

3. Factory Module Descriptions

This chapter is about the Modules that have been developed by Lightware. The properties and the configuration steps are described in the coming sections.

3.1. Generic TCP/IP Device Module

Introduction

This Module is for controlling any third-party device that can be queried/controlled over TCP/IP protocol.

Dashbord Content

The following status indicator is displayed on the Status board:

Connection state of the device

Defined Parameters

ipAddressOrHost: The IP address or the host name of the device.

portNumber: Port to use when connecting.

permanent: Boolean Parameter to determine if the connection should be kept open and not only for sending messages (receiving data is not available if false).

autoConnect: Boolean Parameter to determine if client should automatically retry the connection if not connected.

autoConnectInterval: Interval (in ms) for trying to connect.

frameDelimiter: Delimiter to determine the end of a frame (e.g. \r\n).

frameDelimiterIsHex: Specifying if the provided data is a hexadecimal string.

frameTimeout: If the set time (in ms) has elapsed, the received data is considered as a frame.

keepAliveDelay: Keep alive signal will be sent after the set interval time (in ms) has elapsed.

They can be referred in the JavaScript code as e.g. params.portNumber

Defined Events

connected: The TCP/IP device with the specified ipAddress is connected.

disconnected: The TCP/IP device with the specified ipAddress is disconnected.

error: e.g. Problem in the data transmission, e.g. wrongly set frame delimiter. 'errormessage' Parameter is defined in this Event for the error code.

frameReceived: The received frame; 'frame Parameter' is defined in this Event. It can be used to analyse the content of the received frame.

Defined Methods

send: Sending a text message without a delimiter. 'message' Parameter is defined in this Method.

sendFrame: Sending a text message with a frame delimiter. 'message' Parameter is defined in this Method.

sendHex: Sending a message in hexadecimal format without delimiter. 'message' Parameter is defined in this Method.

Defined Rules

No Rules are defined in this Module.

Custom Code

The code of the factory module in JavaScript.

ATTENTION!If the GUI tools cannot solve a problem, custom code can be added to the end of the code, but please note that if you upgrade the driver module (blue button) the custom sections will be deleted.

3.2. Generic LW3 Device Module

Introduction

This Module is for controlling a Lightware device that supports LW3 protocol. Please refer to the User's Manual of the desired Lightware device for whether it can be controlled with LW3 commands.

Dashbord Content

The following status indicators are displayed on the Status board:

Connection state of the device

Manufacturer name

Product name

Part number

Serial number

FW package version

Defined Parameters

ipAddress

portNumber

They can be referred in the JavaScript code as e.g. params.ipAddress

Defined Events

connected: The LW3 device with the specified ipAddress is connected.

disconnected: The LW3 device with the specified ipAddress is disconnected.

LW3 property changed: The value of a specific LW3 property is changed to the defined value. 'path', 'property' and 'value' Parameters are defined in this Event.

Defined Methods

These methods can be used the same way as the ordinary LW3 GET, SET, OPEN, CLOSE and CALL commands.

get: Querying the value of a specific property (with path). 'path' and 'property' Parameters are defined in this Method.

set: Setting the value of a specific writable property (with path). 'path', 'property' and 'value' Parameters are defined in this Method.

open: Subscribing to a specific node. It means that the user will get a notification if the property changes. 'path' Parameter is defined in this Method.

close: Unsubscribing from a specific node. 'path' Parameter is defined in this Method.

callMethod: Calling a specific LW3 Method; does not work for an LW3 property. 'path' and 'Method' Parameters are defined in this Method (Parameters are optional). Please note that wildchar (*) cannot be used in case of the 'path' Parameter.

Defined Rules

No Rules are defined in this Module.

Custom Code

The code of the factory module in JavaScript.

ATTENTION!If the GUI tools cannot solve a problem, custom code can be added to the end of the code, but please note that if you upgrade the driver module (blue button) the custom sections will be deleted.

3.3. Taurus UCX/CTU/MMX2 Driver Module

Introduction

This Module is for controlling Lightware's UCX, DCX, MMX2 devices and the TPN-CTU-X50 conrol unit with a few Events and Methods. The Module covers the following models:

UCX-2x1-HC30

UCX-2x2-H30

UCX-4x2-HC30

UCX-4x2-HC30D

UCX-2x1-HC40

UCX-2x2-H40

UCX-4x3-HC40

UCX-4x2-HC40

UCX-4x2-HC40D

UCX-4x3-HC40-BD

DCX-2x1-HC10

MMX2-4x3-H20

MMX2-4x1-H20

UCX-4x3-TPX-TX20

UCX-2x1-TPX-TX20

UCX-3x3-TPX-RX20

UCX-4x3-TPN-TX20

UCX-2x1-TPN-TX20

TPN-CTU-X50

Dashbord Content

The following status indicators are displayed on the Status board in the row of the Instance:

Connection state of the device

Firmware package version

Product name

Overall health status

Outputs' source

Outputs' connection state

Outputs' signal presence

USB host input (if any)

Defined Parameters

ipAddress

connectionType

=Raw TCP

=Websocket

=Secure Websocket

authenticationType

=no authentication

=basic authentication

username

password

They can be referred in the JavaScript code as e.g. params.ipAddress

Defined Events

connected: The UCX/CTU/MMX2 device with the specified ipAddress is connected.

disconnected: The UCX/CTU/MMX2 device with the specified ipAddress is disconnected.

sourceInputChanged: Another source is switched to the specified output. 'outoutPort' and 'sourcePort' Parameters are defined in this Event.

outputConnectedStatusChanged: Sink device is connected/disconnected to/from the specified output. 'outputPort' and 'status' Parameters are defined in this Event.

outputSignalPresentStatusChanged: The signal presence is changed on the specified output (e.g. signal is present/not present). 'outputPort' and 'status' Parameters are defined in this Event.

usbHostChanged: Another USB host device is selected for the USB peripherals. 'sourcePort' Parameter is defined in this Event to specify the USB input port.

overallHealthChanged: The value of the /V1/MANAGEMENT/HEALTH/OverallHealthState property is changed. 'healthStatus' Parameter is defined in the Event.

healthAlert: The value of a specific Parameter under /V1/MANAGEMENT/HEALTH node is changed to the defined value. 'property' and 'value' Parameters are defined in this Event.

LW3 property changed: The value of a specific LW3 property is changed to the defined value. 'path', 'property' and 'value' Parameters are defined in this Event.

Defined Methods

get: Querying the value of a specific property (with path). 'path' and 'property' Parameters are defined in this Method.

set: Setting the value of a specific writable property (with path). 'path', 'property'and 'value' Parameters are defined in this Method.

open: Subscribing to a specific node. It means that the user will get a notification if the property changes. 'path' Parameter is defined in this Method.

close: Unsubscribing from a specific node. 'path' Parameter is defined in this Method.

callMethod: Calling a specific LW3 Method; does not work for an LW3 property. 'path', 'Method' and 'Parameters' are defined in this Method (Parameters are optional.)

switchCrosspoint: Changing the crosspoint state of a specific layer (AUDIO, VIDEO or USB). Please note that USB is available only for specific models.

setGpioDirection: Setting the direction (input/output) of a specific GPIO pin. 'port' and 'direction' Parameters are defined in this Method.

setGpioState: Setting the state (low/high) of a specific GPIO pin. 'port' and 'state' Parameters are defined in this Method.

emulateEdid: Setting an EDID (source) to emulate on a specific input port (destination). 'source' and 'destination' Parameters are defined in this Method. Source can be: factory, dynamic, user. Destination can be: emulated.

uploadEdid: Uploading a HEX-format EDID to a User EDID slot. Target and data Parameters are defined in this Method.

changeAnalogAudioVolumeDB: Setting the volume level of a specific analog audio output in dB. 'port' and 'value' Parameters are defined in this Method.

changeAnalogAudioVolumePercent: Setting the volume level of a specific analog audio output in percentage. 'port'and 'value' Parameters are defined in this Method.

For further details about the LW3 properties or Methods, please see the User's Manual of the device.

Defined Rules

No Rules are defined in this Module.

Custom Code

The code of the factory module in JavaScript.

ATTENTION!If the GUI tools cannot solve a problem, custom code can be added to the end of the code, but please note that if you upgrade the driver module (blue button) the custom sections will be deleted.

3.4. Taurus CEC Driver Module

Introduction

This Module is for sending CEC commands (with REST API) to a sink (display) device connected to Lightware's UCX or MMX2 devices over HDMI output.

INFO:Since LARA cannot access to a hardware directly, the REST API interface is used for this purpose. That's why the TCP IP port number and physical connection is necessary for the communication.

Dashbord Content

The following status indicators are displayed on the Status board in the row of the Instance:

Connection state of the device

Controlled output port

Last CEC command timestamp (optional)

Last CEC command status (optional)

Defined Parameters

outputPort: Video output port of the UCX/MMX2 device for CEC command requests.

idlePollingFrequency: Time in seconds for CEC polling on output (0 = no idle polling).

ipAddressOrHost: The IP address or the host name of the device.

protocol: Protocol to be used for connection.

portNumber: Port number (80 for HTTP, 443 for HTTPS) to be used for connection.

authenticationType: Enable or disable basic authentication.

username: User name for basic authentication.

password: Password for basic authentication.

customHeaders: Setting custom headers with the following syntax: header-name:value.

cecMessageStats: Enable the last sent CEC message statistics on the Status Board.

debugMode: Enables the debug mode for sent CEC messages. All of the details of the messages will be printed to the console.

They can be referred in the JavaScript code as e.g. params.outputPort.

Defined Events

error: The CEC command sending was not successful.

availableOnCEC: The device responds to CEC REST requests.

unavailableOnCEC: Device do not respond to CEC REST requests.

Defined Methods

powerOn: Sending the Power On CEC command.

imageViewOn: Sending the Image View On CEC command (use this if the Power On command does not work).

powerOff: Sending the Power Off CEC command.

standby: Sending the Standby CEC command (use this if the Power Off command does not work).

mute: Sending the Mute CEC command.

unmute: Sending the Unmute CEC command.

volumeUp: Sending the Volume Up CEC command.

volumeDown: Sending the Volume Down CEC command.

customCommand: Sending a custom command via CEC. The command Parameter is defined for this purpose in this Method. The custom command can be a HEX string. Only hexadecimal characters are allowed, spaces can be used as delimiters.

Defined Rules

No Rules are defined in this Module.

Custom Code

The code of the factory module in JavaScript.

ATTENTION!If the GUI tools cannot solve a problem, custom code can be added to the end of the code, but please note that if you upgrade the driver module (blue button) the custom sections will be deleted.

3.5. Generic Rest Client Driver Module

Introduction

This Module is for handling REST API-based communication.

Dashbord Content

Last request timestamp: Last request status:

Defined Parameters

certAuthEnable: Enabling certificate-based authentication. Disable this when communicating with Lightware devices via HTTPS.

=true

=false

ipAddressOrHost: IP address or host name of device.

protocol: Protocol to be used for connection:

=HTTP

=HTTPS

portNumber: 80 for HTTP, 443 for HTTPS connection.

authenticationType:

=No authentication

=Basic authentication

username: user name for basic authentication.

password: password for basic authentication.

customHeaders: Setting custom headers with the following syntax: header-name:value.

They can be referred in the JavaScript code as e.g. params.username.

Defined Events

error

responseReceived

Defined Methods

put: PUT Method. Defined Parameters:

=path: string type

=Parameters: JSON type (optional)

=customHeaders: JSON type (optional)

post: POST Method. Defined Parameters:

=path: string type

=Parameters: JSON type (optional)

=customHeaders: JSON type (optional)

get: GET Method. Defined Parameters:

=path: string type

=Parameters: JSON type (optional)

=customHeaders: JSON type (optional)

del: DEL Method. Defined Parameters:

=path: string type

=Parameters: JSON type (optional)

=customHeaders: JSON type (optional)

Defined Rules

No Rules are defined in this Module.

Custom Code

The code of the factory module in JavaScript.

ATTENTION!If the GUI tools cannot solve a problem, custom code can be added to the end of the code, but please note that if you upgrade the driver module (blue button) the custom sections will be deleted.

3.6. Occupancy Sensor and Serial Message Script Module

Introduction

This script Module is for Lightware Taurus and MMX2 series devices for sending serial messages based on the occupancy sensor status.

Dashbord Content

Connection state: UCX/MMX2 device connection state

OCS Status: low/high level state

Serial Port config: optional

Defined Parameters

ipAddress

connectionType

=Raw TCP

=Websocket

=Secure Websocket

authenticationType

=No authentication

=Basic authentication

username

password

serialPort: port number (e.g. P1)

baudRate: Baud rate of the port (e.g. 9600)

stopBits: stop bits (e.g. 1)

parity: parity setting (e.g. None)

occupiedMessageType:

=string (it may contain unicode characters e.g. ˛\u000d for CR)

=HEX

occupiedMessageInput

freeMessageTimeout: timeout in seconds.

freeMessageType:

=string (it may contain unicode characters e.g. ˛\u000d for CR)

=HEX

freeMessageInput: If type is HEX, these formats are accepted: A0B1... or A0 B1... or 0xA0 0xB1... or \xA0 \xB1...

showSerialPortConfig: if enabled, the serial port connection status icon is displayed in the dashboard.

They can be referred in the JavaScript code as e.g. params.ipAddress

Defined Events

connected

disconnected

error

ocsStatusChanged

Defined Methods

No Methods are defined in this Module.

Defined Rules

No Rules are defined in this Module.

Custom Code

The code of the factory module in JavaScript.

ATTENTION!If the GUI tools cannot solve a problem, custom code can be added to the end of the code, but please note that if you upgrade the driver module (blue button) the custom sections will be deleted.

3.7. Signal Present and Serial Message Script Module

Introduction

This script Module is for Lightware Taurus and MMX2 series devices for sending serial messages based on the signal present status or connected state.

Dashbord Content

Connection state: UCX/MMX2 device connection state

Watched Video Port: input/output port ID

Signal Present: signal presence / connected state

Serial Port config: optional

Defined Parameters

ipAddress

connectionType

=Raw TCP

=Websocket

=Secure Websocket

authenticationType

=No authentication

=Basic authentication

username

password

serialPort: port number (e.g. P1)

baudRate: Baud rate of the port (e.g. 9600)

stopBits: stop bits (e.g. 1)

parity: parity setting (e.g. None)

portToWatch: input/output port ID (e.g. I1, O3, etc)

propertyToWatch: the watched property of the port (Signal present / Connected)

messageTypeOnTrue:

=string (it may contain unicode characters e.g. \u000d for CR)

=HEX

messageOnTrue: If type is HEX, these formats are accepted: A0B1... or A0 B1... or 0xA0 0xB1... or \xA0 \xB1...

timeoutBeforeMessage: timeout before message sending in seconds.

messageOnFalse:

=string (it may contain unicode characters e.g. \u000d for CR)

=HEX

messageOnFalse: If type is HEX, these formats are accepted: A0B1... or A0 B1... or 0xA0 0xB1... or \xA0 \xB1...

showSerialPortConfig: if enabled, the serial port connection status icon is displayed in the dashboard.

They can be referred to the JavaScript code as e.g. params.ipAddress

Defined Events

connected

disconnected

error

ocsStatusChanged

Defined Methods

No Methods are defined in this Module.

Defined Rules

No Rules are defined in this Module.

Custom Code

The code of the factory module in JavaScript.

ATTENTION!If the GUI tools cannot solve a problem, custom code can be added to the end of the code, but please note that if you upgrade the driver module (blue button) the custom sections will be deleted.

3.8. SDVoE Driver Module

Introduction

This Module is for discovering Lightware's TPN, OPTN and UCX-TPN devices on the network, and controlling them with a few Events and Methods. The Module covers the following models:

TPN-CTU-X50

UCX-2x1-TPN-TX20

UCX-4x3-TPN-TX20

The Module supports discovering and managing the following SDVoE-based endpoint models on the network:

UCX-2x1-TPN-TX20

UCX-4x3-TPN-TX20

HDMI-TPN-TX107

HDMI-TPN-TX207AU2K

HDMI-TPN-RX107

HDMI-TPN-RX107AU2K

HDMI-TPN-RX107A-SR

HDMI-TPN-RX107AU2K-SR

HDMI-OPTN-TX100A

HDMI-OPTN-TX200AU2K

HDMI-OPTN-RX100A

HDMI-OPTN-RX100AU2K

Dashboard Content

The following status indicators are displayed on the Status board in the row of the Instance:

Connection

TX

RX

Selected devices

Missing devices

Defined Parameters

connectionType

=Raw TCP

=Websocket

=Secure Websocket

ipAddressOrHost: IP address or host name of device.

portNumber: 80 for HTTP, 443 for HTTPS connection.

Status Variables

clientConnected: Indicates if there is an active connection with the SDVoE Control Server.

txCount: The number of TX devices

rxCount: The number of RX devices

selectedDevicesCount: The number of selected devices.

missingDevices: The missing device(s).

Defined Events

sdvoeDisconnected: SDVoE Control Server is disconnected.

sdvoeConnected: SDVoE Control Server is connected.

deviceVideoSwitched: Crosspoint has been changed.

deviceAudioSwitched: Crosspoint has been changed.

deviceConnected: Connected a new SDVoE device.

deviceDisconnected: SDVoE device is disconnected.

userpanelSettingsChanged: Userpanel Settings changed.

Defined Methods

switch: Switch a transmitter to a receiver. If the transmitter is already connected to a receiver, it will be disconnected first.

leave: Will remove one or more connections.

join: Will join a transmitter to a receiver on a given layer. Layer can be 'HDMI' or 'HDMI_AUDIO'.

logAllDevices: Log all available devices on the network to the debug output.

getDeviceList: For internal use in communicating with the user panel. Returns the selected devices on the network.

getConnections: For internal use in communicating with the user panel. Returns the connections of the selected devices on the network.

Defined Rules

No Rules are defined in this Module.

Custom Code

The code of the factory module in JavaScript.

ATTENTION!If the GUI tools cannot solve a problem, custom code can be added to the end of the code, but please note that if you upgrade the driver module (blue button) the custom sections will be deleted.

3.9. Icron USB 2.0 Driver Module

Introduction

This Module is for discovering Lightware's UCX-TPN extenders and -U2K series (Icron USB 2.0) endpoint devices on the network and controlling them with a few Events and Methods. The Module covers the following models:

TPN-CTU-X50

UCX-2x1-TPN-TX20

UCX-4x3-TPN-TX20

The Module supports discovering and managing the following Icron-based endpoint models on the network:

UCX-2x1-TPN-TX20

UCX-4x3-TPN-TX20

HDMI-TPN-TX207AU2K

HDMI-TPN-RX107AU2K

HDMI-TPN-RX107AU2K-SR

HDMI-OPTN-TX200AU2K

HDMI-OPTN-RX100AU2K

Dashboard Content

The following status indicators are displayed on the Status board in the row of the Instance:

Connection

LEX

REX

Selected devices

Missing devices

Defined Parameters

pollingInterval: How often to poll the device for status (ms). 5000 is the recommended value.

Status Variables

clientConnected: Indicates if there is an active connection.

txCount: The number of LEX devices

rxCount: The number of REX devices

selectedDevicesCount: The number of selected devices.

missingDevices: The missing device(s).

Defined Events

connected: ICRON is connected.

disconnected: ICRON is disconnected.

switched: Will be fired when a change is detected in the pairings of a LEX.

deviceAudioSwitched: Crosspoint has been changed.

deviceConnected: Device has been connected.

deviceDisconnected: Device has been disconnected.

Defined Methods

switch: Switch a LEX to a REX, while all other connections are removed from the LEX.

leave: Will disconnect two devices. If the second parameter is not provided, it will disconnect all devices from the first one.

join: Will connect two devices.

logAllDevices: Intended for debug usage. It will list all devices.

setStreamOptimizationMode: Set the stream optimization mode: None/SUI/MSA.

getStreamOptimizationMode: Get the stream optimization mode: None/SUI/MSA.

getDeviceList: For internal use in communicating with the user panel. Returns the selected devices on the network.

getConnections: For internal use in communicating with the user panel. Returns the connections of the selected devices on the network.

Defined Rules

No Rules are defined in this Module.

Custom Code

The code of the factory module in JavaScript.

ATTENTION!If the GUI tools cannot solve a problem, custom code can be added to the end of the code, but please note that if you upgrade the driver module (blue button) the custom sections will be deleted.

3.10. Cisco Webex Module

Supported Cisco Devices

The following Cisco devices are supported by this Module:

Cisco Webex Room Kit

Cisco Webex Room Kit Mini

Cisco Webex Room Kit Plus

Cisco Webex Room Kit Pro

Cisco Webex Codec Plus

Cisco Webex Codec Pro

Cisco Webex Desk Pro

Cisco Webex Room 70 G2

Cisco Telepresence SX20

Cisco Telepresence SX80

Cisco DX70

Cisco DX80

Cisco MX700

Cisco MX800

Cisco Room Bar

Cisco Room Kit EQ

Cisco Board Pro

The Purpose of This Module

The following main benefits can be achieved by using Taurus/MMX2 devices and LARA with this Module:

Bring Your Own Device (BYOD) mode: adding inputs to the Cisco Codec: thus more video sources (e.g. laptops) can be shared.

Camera share option: using the high quality camera and audio system of the Codec for other meeting purposes like a Zoom, Skype, etc. conference for a connected PC/laptop.

BYOD Mode

Cisco Codecs usually contain only one HDMI input. It can be increased by connecting a Taurus/MMX2 device to that input port, thus up to four devices can be connected. Furthermore, certain Taurus models contain USB-C ports, allowing another connection type. When video signal is detected on a video input port of the Taurus device, it will be visible on the UI of the Codec. After that the source can be selected as a BYOD source. Each input can be labelled with a unique name to display in the UI of the Codec.

Camera Share Option

It may happen that a video conference is taking place not via the Webex service, but with one of the particpant's laptop. The camera and the audio system of the Codec is much more suitable for this purpose than a laptop, so this feature means the camera and the audio devices can be shared to a PC/laptop connected over HDMI and USB-B or only USB-C.

3.10.1. Controlling Over Serial Connection

This chapter is about the settings when the Taurus and the Codec are connected via Serial port.

Checklist for the Taurus/MMX2 Device

Before connecting and configuring the Taurus to a Cisco Codec, the following have to be checked:

The serial port settings must match in the Taurus and in the Codec: 115200 Baud, 8 N, 1 (based on Cisco Codecs).

Make sure the autoselect is disabled on the video output ports as well as on USB ports.

Check if the Serial over IP port is enabled: 8001 for P1, 8002 for P2 (LDC/Settings/Network).

Set the Video and USB-C ports to umuted and unlocked state.

Pay attention to the physical serial port: use the port where the cable is connected to:

Checklist for the Codec

The serial port settings must match in the Taurus and in the Codec.

Create a user name and set a password in the Codec. (Note them, these should be entered when configuring the module in LARA.)

Privileges should be enabled for:

=RoomControl,

=Integrator,

=Admin.

The following option shall be disabled:

=Require passphrase change on next user sign in.

If you install a USB capture device for camera share, e.g. Inogeni 4KXUSB3, connect it to the last HDMI output of the Codec.

INFO:Certain Cisco codecs do not have separate RS-232 port, but the dedicated USB port can be used for this purpose. In that case, connect a USB-Serial (FTD) cable between the Taurus and the Codec.

Instance Parameters

Create an Instance from the module 'ciscowebex' and set the instance parameters as follows:

ATTENTION!Do not leave the value of the parameter in 'empty' state if it can be selected from a drop-down menu.

Instance Name and Name of the Room

Set them as you wish.

Codec Type

Select the Cisco model you install.

Connection Type

Select Serial port (RS232).

INFO:Ethernet connection is not required between the Taurus and the Codec. These packets are transferred internally, between LARA and the Taurus TCP Serial Gateway.

Connection Restart Timeout

The default value is 5000 milisecs waited before the module restarts after an error.

IP Address of the Cisco Device

Leave it as is: 'localhost'.

Serial Port Number of the Taurus

Write the index number of the port without letter, e.g. 1 for P1 RS-232 port.

Username for Cisco Codec Connection

As set in the Codec previously.

Password for Cisco Codec Connection

As set in the Codec previously.

Cisco Codec Output Port Connection Settings (#1/#2/#3)

DIFFERENCE:The available port numbers are Codec-dependent.

If you have a display device connected to a certain output, set it to 'Display'.

If you connect a USB capture device to the last HDMI output for camera share option, set the 'Last HDMI Output as USB Capture' setting to 'true'. In this case the Output connection setting on that output does not matter.

Set 'no connection' for the output that is not used.

Taurus Settings

The default settings work, no need to change.

Taurus Input Port Settings

Set the labels that will be visible on the Cisco UI (BYOD selection). If you leave a field empty, the input will not be placed to the UI as a source. ASCII characters (space also) are accepted.

ATTENTION!For Cisco-compatibility reasons the HDCP will be disabled on the inputs that are defined in the BYOD selection.

Taurus Output Port Connections

Select 'Cisco Device Input #1' for Output#1. The other output selectors are reserved for future developments.

Enable USB Parallel Switching

If set to 'true', the USB crosspoint will follow the video crosspoint.

Enable SignalPresent detection on inputs

If set to 'true', the Taurus device will offer the BYOD device selection prompt when signal is present on the HDMI input.

3.10.2. Controlling Over Ethernet Connection

This chapter is about the settings when the Taurus and the Codec are connected via Ethernet.

Checklist for the Taurus/MMX2 Device

Make sure that the Taurus and the Codec can communicate with each other over Ethernet.

Check the VLAN preset settings of the Taurus (Control/Ethernet page in LDC): the Codec and the MCU must be in the same VLAN.

Make sure the autoselect is disabled on the video output ports as well as on USB ports.

Set the Video and USB-C ports to umuted and unlocked state.

Checklist for the Codec

Websocket has to be enabled (the integration works with wss (secured websocket) communication). Open the Codec web interface:

=Settings Configurations NetworkServices Websocket FollowHTTPService.

=Settings Configurations NetworkServices HTTP Mode HTTPS.

=Save the settings.

Create a user name and set a password in the Codec. (Note them, these should be entered when configuring the Module in LARA.)

Privileges should be enabled for:

=RoomControl,

=Integrator,

=Admin.

The following option shall be disabled:

=Require passphrase change on next user sign in.

If you install a USB capture device for camera share, e.g. Inogeni 4XKUSB3, connect it to the last HDMI output of the Codec.

Instance Parameters

Create an Instance from the Module 'ciscowebex' and set the Instance Parameters as follows:

ATTENTION!Do not leave the value of the Parameter in 'empty' state if it can be selected from a drop-down menu.

Instance Name and Name of the Room

Set them as you wish.

Codec Type

Select the Cisco model you install.

Connection Type

Select Websocket.

Connection Restart Timeout

The default value is 5000 milisecs waited before the module restarts after an error.

IP Address of the Cisco Device

Type the IP address of the Codec.

Serial Port Number of the Taurus

N/A

Username for Cisco Codec Connection

As set in the Codec previously.

Password for Cisco Codec Connection

As set in the Codec previously.

Cisco Codec Output Port Connection Settings (#1/#2/#3)

DIFFERENCE:The available port number is Codec-dependent.

If you have a display device connected to a certain output, set it to 'Display'.

If you connect a USB capture device to the last HDMI output for camera share option, set the 'Last HDMI Output as USB Capture' setting to 'true'. In this case the Output connection setting on that output does not matter.

Set 'no connection' for the output that is not used.

Taurus Settings

The default settings work, no need to change.

Taurus Input Port Settings

Set the labels that will be visible on the Cisco UI (BYOD selection). If you leave a field empty, that input will not be placed to the UI as a source. ASCII characters (space also) are accepted.

ATTENTION!For Cisco-compatibility reasons the HDCP will be disabled on the inputs that are defined in the BYOD selection.

Taurus Output Port Connections

Select 'Cisco Device Input #1' for Output#1. The other output selectors are reserved for future developments.

Enable USB Parallel Switching

If set to true, the USB crosspoint will follow the video crosspoint.

Enable SignalPresent detection on inputs

If set to 'true', the Taurus device will offer the BYOD device selection prompt when signal is present on the HDMI input.

3.10.3. Further Notices

Webex Mode

Webex mode is activated if:

The Codec is started, or

All devices are disconnected from the Codec.

INFO:Half Wake and Standby modes are active in Webex mode, but in BYOD mode these modes are inactive.

After Restart

If the Codec, the UCX/MMX2 or LARA is restarted for some reason, the system must recover in the same working state as it has been previously.

3.10.4. Known Issues

'Preset does not exist'

This message may appear in the log window when the Codec is a Cisco Room Kit Mini. This entry does not mean an error.

'Unknown widget: 'byodselector'

This message may appear in the log window when the Codec is a Cisco Room Kit Mini. This entry does not mean an error.

For camera sharing option

Please connect the USB capture device (or the RoomKit Mini USB-C cable) to the Taurus port USB-A #1:

Unused Button

It may happen in case of Room Kit Mini and Room Kit Bar Codecs that the UI contains a button with the following label: 'Call from laptop'. This button has no function in this case.

3.10.5. Integration with the Cisco Codec

Main Menu

After a successful setup a new button will appear in the Main menu of the Codec: BYOD Selection.

BYOD Selection

After pressing the 'BYOD Selection' button, a window appears on the UI of the Codec. On the bottom of the screen the defined and available inputs can be seen with the labels set in the Instance *.

* If there is no USB layer in the Lightware device, the label below the 'BYOD selection' is: 'Connect your source via HDMI'.

When a source is selected:

The video signal of the selected source is displayed on all outputs of the Codec except the last HDMI output if a USB capture device is installed on that port.

Not applicable buttons will be hidden in the main menu.

The USB crosspoint of the Taurus UCX device will follow the video crosspoint state if the 'Enable USB parallel switching' option is 'true'.

The 'SpeakerTrack' feature of the camera is turned on – if it is supported.

The microphone signal will be sent via the analog audio output of the Codec to the USB capture device. *

The 'Do not disturb' mode of the Codec will be switched on with default timeout (24 h).

The automatic standby mode is deactivated in the Codec.

When selecting 'Webex' again:

The video output of the Codec will be the default UI content.

Previously hidden buttons will appear again in the menu.

The 'SpeakerTrack' feature of the camera will be still on – if it is supported.

The analog audio output of the Codec will be switched off. *

The 'Do not disturb' mode of the Codec will be switched off.

The 'Halfwake' mode must be activeted in the Codec after 2 minutes of idle time.

* Does not refer to Cisco Webex Room Kit Mini.

If a new source is connected to the UCX/MMX2 device, the following window appears:

3.11. Sink Driver Modules

Sink devices from different brands can be controlled with the following driver modules:

LG Signage televisions - see the details in the LG Signage Driver Module section.

Sony Bravia televisions - see the details in the Sony Bravia Driver Module section.

PJLink projectors - see the details in the PJLink Protocol Driver section.

3.11.1. LG Signage Driver Module

Introduction

This Module is for controlling the LG Signage compatible displays with a few Events and Methods.

Dashboard Content

The following status indicators are displayed on the Status board in the row of the Instance:

Connection

Power status

Volume level

Mute status

Selected input

Defined Parameters

macAddress: MAC Address of the device

ipAddressOrHost: IP address / hostname of the device.

portNumber: Port number of the device, default is 9761.

setId: Set ID of the controlled device.

Status Variables

clientConnected: Indicates if there is an active TCP connection with the device.

powerStatus: Indicates the power status of the display.

volumeLevel: Indicates the volume status of the display.

muteStatus: Indicates the mute status of the display.

selectedInput: Indicates the selected input of the display.

Defined Events

connected: Client connected.

disconnected: Client disconnected.

Defined Methods

powerOn: Powers on the display by Wake On Lan. During this sequence there is no status report.

powerOff: Powers off the display. Usally means standby mode.

mute: Mutes the audio output. It only works if a valid input is selected.

unmute: Unmutes the audio output. It only works if a valid input is selected.

setVolume: Sets the volume level of the display, if it is supported. It only works if a valid input is selected.

setInput: Input name of the input port.

Defined Rules

No Rules are defined in this Module.

Custom Code

The code of the factory module in JavaScript.

ATTENTION!If the GUI tools cannot solve a problem, custom code can be added to the end of the code, but please note that if you upgrade the driver module (blue button) the custom sections will be deleted.

3.11.2. Sony Bravia Driver Module

Introduction

This Module is for controlling the Sony Bravia displays with a few Events and Methods.

Dashboard Content

The following status indicators are displayed on the Status board in the row of the Instance:

Connection

Power status

Volume level

Mute status

Selected input

Defined Parameters

ipAddressOrHost: IP address or hostname of the device.

idlePollingFrequency: Time in seconds for polling display status (0 = no idle polling).

controlType: Control type used by the driver.

authenticationType: Authentication can be enabled in "REST API" control type, otherwise ignored. Pre-Shared Key authentication is a MUST for several request types, if not present errors may occur!

preSharedKey: Pre-Shared Key for authentication. Only used if "Authentication" is set to "Pre-Shared Key", otherwise ignored.

Status Variables

clientConnected: Indicates if the client is connected with the device.

powerStatus: Indicates the power status of the display.

volumeLevel: Indicates the volume status of the display.

muteStatus: Indicates the mute status of the display.

selectedInput: Indicates the selected input of the display.

Defined Events

connected: The communication client managed to connect to the device.

disconnected: The communication client disconnected from the device.

error: Error event.

selectedInputChanged: Device's selected input status changed.

volumeLevelChanged: Device's volume status changed.

powerStatusChanged: Device's power status changed.

muteStatusChanged: Device's mute status changed.

Defined Methods

powerOn: Powers on the display by Wake On Lan. During this sequence there is no status report.

powerOff: Powers off the display. Usally means standby mode.

mute: Mutes the audio output. It only works if a valid input is selected.

unmute: Unmutes the audio output. It only works if a valid input is selected.

setVolume: Sets the volume level of the display, if it is supported. It only works if a valid input is selected.

setInput: Input name of the input port.

Defined Rules

No Rules are defined in this Module.

Custom Code

The code of the factory module in JavaScript.

ATTENTION!If the GUI tools cannot solve a problem, custom code can be added to the end of the code, but please note that if you upgrade the driver module (blue button) the custom sections will be deleted.

3.11.3. PJLink Protocol Driver

Introduction

This Module is for controlling the PJLink Projectors with a few Events and Methods.

Dashboard Content

The following status indicators are displayed on the Status board in the row of the Instance:

Connection

Authentication status

Power status

Mute status

Selected input

Lamp hours

Manufacturer name

Product name

Projector name

Defined Parameters

ipAddress: IP address of the projector/display.

port: TCP port of the projector/display, default is 4352.

password: Password for basic authentication.

Status Variables

clientConnected: Indicates if there is an active TCP connection with the device.

powerStatus: Indicates the power status of the device.

authenticationStatus: Indicates the authentication status of the device.

selectedInput: Indicates the selected input of the device.

muteStatus: Indicates the mute status of the device.

lampHours: Indicates the lamp hours of the display.

Defined Events

No Events are defined in this Module.

Defined Methods

powerOn: Powers on the display by Wake On Lan. During this sequence there is no status report.

powerOff: Powers off the display. Usally means standby mode.

mute: Mutes the audio output. It only works if a valid input is selected.

unmute: Unmutes the audio output. It only works if a valid input is selected.

switchInput: Input type of the port.

Defined Rules

No Rules are defined in this Module.

Custom Code

The code of the factory module in JavaScript.

ATTENTION!If the GUI tools cannot solve a problem, custom code can be added to the end of the code, but please note that if you upgrade the driver module (blue button) the custom sections will be deleted.

4

4. User Module Descriptions

This chapter is about the Modules that have been developed by Lightware. The properties and the configuration steps are described in the coming sections.

4.1. Touchscreen UI Module

Introduction

The Module offers ready-to-use user interface templates for touchscreen devices, which provide controlling various type of meeting or huddle rooms.

Designs

2 different design sets

Apply each design set for all above templates

Devices

The default templates contains the following devices and control tools:

Room: On / Off

Camera: Move Up / Down / Right / Left / Zoom in / Zoom out

Microphone: Mute / Unmute

Display: Turn on / Turn off

Volume: Increase / Decrease

Lights: On / Off

TIPS AND TRICKS:The built-in templates can be customized freely and users can add new buttons and features to the touchpanel as well. See more personalization samples in the Personalizing of the UI section.

4.1.1. Huddle Room Template

Devices in the template:

Room

Camera

Microphone

Display

Volume slider

4.1.2. Meeting Room Template

Devices in the template:

Room

Camera

Microphone

Two displays

Volume slider

4.1.3. Meeting Room with Light Control Template

Devices in the template:

Room

Camera

Microphone

Two displays

Volume slider

Light

4.1.4. TPN Small Room Template

The template is recommended to use as the dedicated user interface for the SDVoE Driver Module.

Tools in the template:

Crosspoint view for the TPN and OPTN AV matrix.

4.1.5. Icron Small Room Template

The template is recommended to use as the dedicated user interface for the Icron USB 2.0 Driver Module.

Tools in the template:

Crosspoint view for the Icron USB 2.0 matrix.

4.1.6. Dashboard Content

The following status indicator is displayed on the Status board:

QR code and link to the Touchscreen UI

Clicking on the icon pops up the scannable QR code and the link of the touchscreen UI.

4.1.7. Editing of the Module

Click on the icon to edit the Parameters of the Module and to get more information about it.

The following sections are available in the user panel Module:

Info: it can be filled with basic user information about the user panel like author, version, etc.

Parameters: Parameters can be added to the Module which can be used for the user panel. User defined Parameters can be used in Javascript code only.

Events: predefined Events can be cusomized or new Events can be added to the user panel interActions and a specific change (user interAction or Parameter change) that can be used as a Trigger.

Methods: Methods can be added to Module and Actions to run when an Event is triggered.

Rules: predefined Rules can be cusomized or new Rules can be added to the user panel interActions. In case of User Modules, the Rule can be arranged in the Module, Logic Module is not necessary.

Custom code: custom user code in javascript can be uploaded.

Content: the original HTML and CSS code of the chosen template can be reviewed and customized here.

4.1.8. Personalizing of the UI

This section shows how to personalize the touchscreen UI templates through some simple examples. The Huddle Room Light template will be used in the following samples.

Changing of the Company Logo

The template contains a logo which is displayed on the touchscreen UI by default. The logo can be changed easily in few simple steps.

Huddle Room Light template with the default company logo

Uploading the New Logo

Step 1.Edit the user panel Module by clicking on the icon. Go to the Content section and select the img folder.

Editing in the User panel content libraries

TIPS AND TRICKS:The content or the files can be uploaded by drag&drop, too.

Step 2.Upload the new company logo to the img folder. Click on the Upload file icon. Browse the new logo file and upload it. Recommended file extension is .svg. In our example it is the LightwareLogo.svg.

Uploading a new file

Editing of the CSS File

Step 3.Select the style.css and find the row in the code where the logo.svg is actually linked. In our example it is in the row 89. Edit the link of the logo file to the new one like in our example:

Original code:

background: url(./img/logo.svg) no-repeat center left;

Edited code:

background: url(./img/LightwareLogo.svg) no-repeat center left;

Editing of the CSS file

Step 4.Save the style.css by clicking on the Save file icon.

Refreshing of the Touchscreen UI

Step 5.Go the touchscreen panel UI and refresh it in the web browser. The new company logo appears immediately.

Touchscreen UI with the new company logo

Changing the Color of the Buttons

The next few steps show how to change the color of the buttons.

Editing of the CSS File

Step 1.Select the style.css and find the row in the code where the background color of the buttons are defined. In our example it is in the row 155.

Editing of the CSS file

Step 2.Type the wished RGB code after the # character or select it in the color picker pop-up window.

Color picker pop-up window in the CSS editor

Step 3.Save the style.css by clicking on the Save file icon.

Step 4.Go the touchscreen panel UI and refresh it in the web browser. The new button color appears immediately.

The user panel with the new button colors

Adding Feedback Indicators to the Buttons

A feedback from the UI that makes it visible that the interaction actually happened is a valid user requirement. The following section shows how to do it in the touchscreen panel Module.

Example Description

The Display On button shall change its color to green when it is clicked and parallel, the Display Off button shall change its color to grey.

When Display Off button is clicked, its color shall change to green and parallel, the Display On button shall change its color to grey.

Adding Rule Action Steps

Step 1.Edit the user panel Module by clicking on the icon. Navigate to the Rules section and select the Handle displayOn button clicked Rule.

User panel - Rule editor

Step 2.Click on the Add Rule Action step button. Fill the fields with the following values. Click on the Save button when it is done.

Name

DisplayOn color green

Description

Color of the Display On button changes to green when it is clicked.

Select Action step

Set HTML Element CSS Style

HTML Element ID

displayOn

CSS Property name

background-color

CSS Property value

green

Step 3.Click on the Add Rule Action step button again. Fill the fields with the following values. Click on the Save button when it is done.

Name

DisplayOff color grey

Description

Color of the Display Off button changes to grey when Display On is active.

Select Action step

Set HTML Element CSS Style

HTML Element ID

displayOff

CSS Property name

background-color

CSS Property value

grey

Step 4.Navigate to the Rules section and select the Handle displayOff button clicked Rule.

Step 5.Click on the Add Rule Action step button. Fill the fields with the following values. Click on the Save button when it is done.

Name

DisplayOff color green

Description

Color of the Display Off button changes to green when it is clicked.

Select Action step

Set HTML Element CSS Style

HTML Element ID

displayOff

CSS Property name

background-color

CSS Property value

green

Step 6.Click on the Add Rule Action step button again. Fill the fields with the following values. Click on the Save button when it is done.

Name

DisplayOn color grey

Description

Color of the Display On button changes to grey when Display Off is active.

Select Action step

Set HTML Element CSS Style

HTML Element ID

displayOn

CSS Property name

background-color

CSS Property value

grey

Step 7.Click on the Save button to apply the recent changes. Accept to Restart LARA service.

LARA service warning window

Step 8.Go the touchscreen panel UI. After restarting the LARA service the UI will be refreshed automatically and the new button style appears.

The user panel with the new button style

TIPS AND TRICKS:The example above is one possibility to customize the image of the touchscreen panel. Every element that has CSS property can be re-colored / resized / added new element (for example border around the buttons) etc. Only your imagination can set the limit.

5

5. Sample Configuration

This chapter is about building up a whole configuration. The example starts from scratch as LARA contains no configuration.

5.1. Basic LED Toggle

What Will Happen?

A simple button (dry contact) is connected to GPIO PIN1 and an LED to PIN4 of the UCX Taurus device. When the button is pressed, the LED is toggled to be switched on or off.

TIPS AND TRICKS:If you do not have devices to connect to the GPIO, you can Trigger and monitor the state changes in LDC:

Configuration Steps

Step 1.Check the GPIO pin directions in LDC or web LDC and set the desired option.

Step 1.Creating the Driver Module(s).

Step 2.Creating the Logic Module.

Step 3.Creating Instances from the Modules.

Step 4.Creating Events in the Drived Module(s).

Step 5.Creating Rules in the Modules.

Step 6.Starting the configuration.

Step 1. Creating the Driver Module: taurus-ucx-mmx2-Driver

Add new Module

Create Taurus Driver

Step 2. Creating the Logic Module: Logic

Step 3. Creating the Instances from the Modules

Saving the MyTaurus_inst Instance

Saving the myLogic_inst Instance

Step 4. Creating Event(s) in the Driver Module

Step 5. Creating Rules in the Modules

Initializing the GPIO pin in the Taurus when LARA starts – Taurus Module

Adding the first Action step: logging a short message

Adding the second Action step: setting the GPIO pin direction

After that, the Action steps look like this:

Toggle the output level of P4 – Logic Module

Adding the first Action step: logging a short message

Adding the second Action step: toggle the GPIO pin output level

Step 6. Starting the configuration

The Configuration is ready to use, run LARA!

TIPS AND TRICKS:This configuration can be downloaded from Lightware's Cloud storage, so you can compare your work with the solution.

5.2. Configuration Steps for TPN Matrix

Configuration Steps in a Nutshell

Step 1.Creating the Driver module.

Step 2.Creating an Instance from the driver module.

Step 3.Creating the Userpanel module.

Step 4.Creating an Instance from the userpanel module.

Step 5.Starting of the LARA services.

Step 6.Configuration of the UI.

5.2.1. Creating the Driver Module

At first, LARA needs a driver module to handle the SDVoE extenders.

Step 1.Select the Create New Configuration button.

Step 2.Click on the button to create a new module.

Step 3.Fill out the parameters of the new module as follows:

=Category: driver

=Base module: @lwr-lara-modules/sdvoe-driver

=Name: a custom name.

Step 4.Click on the Save button to complete the driver module.

5.2.2. Creating an Instance from the Driver Module

An instance is needed to be created from the driver module as follows:

Step 1.Click on the button to create an instance.

Step 2.Fill out the parameters of the new instance as follows:

=Instance name: a custom name (note down the given name, it must be used later)

=Connection type: WebSocket

=Host: the IP address of the TPN-CTU-X50

=Port: 8080

Step 3.Click on the Save button to complete the instance.

5.2.3. Creating the Userpanel Module

Users need a UI where the crosspoint settings can be managed.

Step 1.Navigate to the Browse Modules tab.

Step 2.Click on the button to create a new module.

Step 3.Fill out the parameters of the new module as follows:

=Category: userpanel

=Template: TPN small room

=Name: a custom name

Step 4.Click on the Save button to complete the driver module.

TIPS AND TRICKS:The built-in templates can be customized freely and users can add new buttons and features to the touchpanel as well. See more personalization samples in the Personalizing of the UI section.

5.2.4. Creating an Instance from the Userpanel Module

An instance is needed to be created from the userpanel module as follows:

Step 1.Click on the button to create an instance.

Step 2.Fill out the parameters of the new instance as follows:

=Instance name: a custom name

=sdvoeInstanceId: the name of the instace created from the driver

Step 3.Click on the Save button to complete the instance.

5.2.5. Starting of the LARA Services

LARA services need to be started by clicking on the button.

Services are not running in LARA

After the services start to run, the status board displays the details of the services.

Services are running in LARA

The services can be stopped by clicking on the button and they can be restarted by clicking on the button.

Information on the Driver Status Board

Field

Value

Description

Connection

Connected

TPN-CTU-X50 is online and managed by the LARA services.

Disconnected

TPN-CTU-X50 is not connected to the LARA services.

TX

<number>

Number of the connected TPN/OPTN series transmitters.

RX

<number>

Number of the connected TPN/OPTN series receivers.

Selected devices

<number>

Number of selected TPN/OPTN series extenders in the Icron UI panel.

Missing devices

<number>

Number of selected TPN/OPTN series extenders in the Icron UI panel that are disconnected from the network.

5.2.6. Configuration of the UI

Accessing of the TPN GUI

Click on the icon in the status board of the TPN driver.

QR code and the direct link to the UI of the driver

Configuration of the Endpoint Devices with TPN GUI

Open the link that guides to the TPN GUI where the transmitters (Source) and the receivers (Sink) can be managed and the crosspoint table can be built.

TPN GUI window

Description

The default device name of the endpoints is the ID of the device. It can be personalized in the Custom name field. Where the User panel checkbox is ticked in, the stream of the endpoint will appear on the Userpanel as a crosspoint possibility.

Select an endpoint device to check the parameters in the Properties section. The panel displays information about the transmitted audio/video stream and in case of scaling receivers (-SR models), the parameters of the scaler can be set.

Crosspoint View on the TPN Userpanel

Click on the icon in the status board of the TPN userpanel:

QR code and the direct link to the userpanel

Open the link that guides to the user panel where the crosspoint settings can be managed.

Crosspoint UI of a sample 6x6 TPN matrix system

5.3. Configuration Steps for Icron USB 2.0

Configuration Steps in a Nutshell

Step 1.Creating the Driver module.

Step 2.Creating an Instance from the driver module.

Step 3.Creating the Userpanel module.

Step 4.Creating an Instance from the userpanel module.

Step 5.Starting of the LARA services.

Step 6.Configuration of the UI.

5.3.1. Creating the Driver Module

At first, LARA needs a driver module to handle the SDVoE extenders.

Step 1.Select the Create New Configuration button.

Step 2.Click on the button to create a new module.

Step 3.Fill out the parameters of the new module as follows:

=Category: driver

=Base module: @lwr-lara-modules/icron-usb20-driver

=Name: a custom name.

Step 4.Click on the Save button to complete the driver module.

5.3.2. Creating an Instance from the Driver Module

An instance is needed to be created from the driver module as follows:

Step 1.Click on the button to create an instance.

Step 2.Fill out the parameters of the new instance as follows:

=Instance name: a custom name (note down the given name, it must be used later)

Step 3.Click on the Save button to complete the instance.

5.3.3. Creating the Userpanel Module

Users need a UI where the crosspoint settings can be managed.

Step 1.Navigate to the Browse Modules tab.

Step 2.Click on the button to create a new module.

Step 3.Fill out the parameters of the new module as follows:

=Category: userpanel

=Template: Icron small room

=Name: a custom name

Step 4.Click on the Save button to complete the driver module.

TIPS AND TRICKS:The built-in templates can be customized freely and users can add new buttons and features to the touchpanel as well. See more personalization samples in the Personalizing of the UI section.

5.3.4. Creating an Instance from the Userpanel Module

An instance is needed to be created from the userpanel module as follows:

Step 1.Click on the button to create an instance.

Step 2.Fill out the parameters of the new instance as follows:

=Instance name: a custom name

=sdvoeInstanceId: the name of the instace created from the driver

Step 3.Click on the Save button to complete the instance.

5.3.5. Starting of the LARA Services

LARA services need to be started by clicking on the button.

Services are not running in LARA

After the services start to run, the status board displays the details of the services.

Services are running in LARA

The services can be stopped by clicking on the button and they can be restarted by clicking on the button.

Information on the Driver Status Board

Field

Value

Description

Connection

Connected

TPN-CTU-X50 is online and managed by the LARA services.

Disconnected

TPN-CTU-X50 is not connected to the LARA services.

LEX

<number>

Number of the connected AU2K series transmitters.

REX

<number>

Number of the connected AU2K series receivers.

Selected devices

<number>

Number of selected AU2K series extenders in the Icron UI panel.

Missing devices

<number>

Number of selected AU2K series extenders in the Icron UI panel that are disconnected from the network.

5.3.6. Configuration of the UI

Accessing of the Icron GUI

Click on the icon in the status board of the Icron USB 2.0 driver.

QR code and the direct link to the UI of the driver

Configuration of the Endpoint Devices with Icron GUI

Open the link that guides to the Icron GUI where the transmitters (Local - LEX) and the receivers (Remote - REX) can be managed and the crosspoint table can be built.

TPN GUI window

Description

The default device name of the endpoints is the ID of the device. It can be personalized in the Custom name field. Where the User panel checkbox is ticked in, the stream of the endpoint will appear on the Userpanel as a crosspoint possibility.

Select an endpoint device to check the parameters in the Properties section. The panel displays information about the IP address and MAC address of the Icron module in the AU2K series endpoint device. Alias can be defined for easier recognition in the crosspoint table.

SUI / MSA setting:

SUI - Simultaneous Users Interaction - this mode is recommended in case of point-multipoint connections (multiple REXes are connected to a single LEX).

MSA - Mass Storage Acceleration

Crosspoint View on the Icron Userpanel

Click on the icon in the status board of the Icron userpanel:

QR code and the direct link to the userpanel

Open the link that guides to the user panel where the crosspoint settings can be managed.

Crosspoint UI of a sample 2x2 Icron USB 2.0 matrix system

Document Revision History

Rev.

Release date

Changes

Editor

v1.0

22-03-2023

Initial version

Laszlo Zsedenyi

v1.1

03-10-2023

User Module chapter (Touchscreen) added; minor corrections and updates.

Tamas Forgacs Laszlo Zsedenyi

v1.2

06-05-2024

Chapter 1-3 have been revised; new Rule-handling and Status variable sections added.

Laszlo Zsedenyi

v1.3

29-08-2024

Added SDVoE and Icron driver modules and step-by-step sections; added Sink driver modules

Tamas Forgacs

Contact Us

sales@lightware.com

+36 1 255 3800

support@lightware.com

+36 1 255 3810

Lightware Visual Engineering PLC.

Peterdy 15, Budapest H-1071, Hungary

www.lightware.com